The EA-10000 Series regenerative DC electronic loads bring a host of capabilities and efficiencies to your application. Active power factor correction minimizes waste drawn from your power grid. Regenerative loads recover energy and feed it back into the grid with >96% efficiency as well as reduce heat, noise and HVAC costs, making them cost-effective and environmentally friendly. True autoranging allows the sinking of maximum power along a wider range of voltage and current values while a suite of optional control interfaces allow computer control in near any manufacturing environment.
ELR series regenerative DC electronic loads feature high power density and input power ratings ranging from 1500W to 30kW with a maximum of 2000VDC. They come standard with a built-in function generator capable of creating arbitrary waveforms for dynamic testing of sources. ELRs can be easily paralleled in racks to achieve 3.84MW of power.

Prev Next

Autoranging Gives Flexibility

EA Elektro-Automatik products have autoranging, which allows the supply or load to operate at max power across a range of voltages and currents, down to 33% of the rated output maximum.

Compare this to traditional power supplies, which can only output their rated power at their max voltage and max current. Applying the maximum voltage to a device under test (DUT) is rare, which means most of the time, that supply is not being used to its full potential.

How does it work? EA sources automatically offer more current at lower voltages (or more voltage at lower currents), allowing the supply to continue outputting the rated power. This allows a single source to address multiple voltage and current combinations that would otherwise require multiple supplies.

 

Regeneration turns waste into savings

EA regenerative electronic loads and bidirectional supplies can recover up to 96% of the energy they sink, that means the AC mains connection is also used as output for the back-feed of the supplied DC energy.

Traditional electronic loads or resistor banks dissipate their sunk power by turning it into heat. This can require large cooling/HVAC solutions and that sunk energy is then lost forever as waste, reducing test and facility efficiency.

Energy recovered by EA loads is fed back into the local facility grid with a mains-synchronized inverter, where that energy can be used by other devices in the facility. If more energy is recovered than used by the facility (a possibility when testing fuel cell output, for example), the energy can be fed back out to the public grid.

Built-In Function Generator

Simplifies Setups Many EA supplies and loads include an integrated function generator that can be used to drive the voltage or current output. All the typical AFG waveforms are available as well as arbitrary capability with sequencing for creating more custom output waveforms. This AFG capability scales with multiple supplies in parallel. The function generator allows the supply to simulate or test complex behaviors like: Simulating a solar cell with accurate open circuit voltage, short circuit current, and maximum power point (MPP) voltage and current. Testing inverter efficiency to CSN EN 50530 standards. Testing LV123, LV124 and LV148 standards for automotive suppliers.

 

Control the way you Control

Using the right control interface simplifies setup and reduces troubleshooting, so the EA-10000 Series supports the AnyBus system allowing for field installable communication options for common industrial interfaces like ProfiNet, CANopen, Modbus-TCP, DeviceNet, EtherCAT, RS-232, and more. These are in addition to standard included interfaces like USB and Ethernet.

Industrial Series for Most Demanding Power Needs

For the highest energy density needs and future-oriented applications, the EA-10000 Industrial Series is available. 6U form factors offer up to 60kW of power, and 19” rack solutions mean you can deliver 300kW of power from only 0.6 m2 of floor space. Combine up to 13 racks for 3.84MW of bidirectional power delivery and recovery. The industrial series are available as a unidirectional power supply (PU), bidirectional power supply (PUB), and regenerative electronic load (PUL).

 

Series Specifications
Series Power Voltage Current
EA-EL 9000 DT Up to 900W 0–80V up to 0–750V 0–5A up to 0–60A
EA-EL 3000 B 400W 0–80 up to 0–500V 0–10A up to 0–60A
EA-EL 9000 T Up to 600W 0–80V up to 0–500V 0–8A up to 0–4.5A

Related Products



Support at Every Step


We provide support, services, comprehensive training and the resources you need. It’s all part of what we do to maximise the value of your VICOM investment.

Services

Value-add services that complement your VICOM system solution and instrument portfolio to provide a total cost of ownership.

Customer Care

Customer service that provides Return Material Authorisation (RMA) for repair and calibration.

Training

Technical education solutions, product training, and blended learning for technicians who are using new products or working with existing tools

Technical Assistance

Technical Assistance Center to assist you in using/configuring products or address issues regarding product performance


How to get started


Interested in a product demonstration? Contact us for more info, receive a price quote, or find out how to buy.

Contact Sales Expert

Request a Quote

Request a Demo