Expandable PIM Analysers – PEM Series
Production testing requires fast and highly reliable PIM analysers. As the spectrum of manufactured products widens, PIM analysis may have to be performed on additional frequencies. Our Expandable PIM Analyzer is can be equipped with one to four different RF Units. Expandable PIM Analyser for Manufacturing and Laboratory.
Features
- Control Unit can control up to 4 different RF Units.
- 3 Measurement Modes: PIM Analyzer, PIM over Time, PIM over Frequency (Frequency Sweep).
- RF Units from 700 MHz up feature forward & reverse PIM (2-port).
- Measures Intermodulation products IM3, IM5 IM7, IM9, IM11 and IM13
Passive Intermodulation (PIM) analyzers measure the amount of unwanted intermodulation signals generated by passive components. Increasing demand for wireless data bandwidth requires networks that operate optimally. Leading global wireless carriers use only low PIM components to guarantee best possible quality of their networks. Since PIM is detrimental to both, network performance and capacity, low PIM components are vital to achieve this goal. PIM is caused by RF components that show non-linear frequency behavior. Reducing PIM to a minimum must be the ultimate goal for manufacturers of RF components.

Whether growing with demand, or offering greatest flexibility with four frequency bands, AWT’s Expandable PIM Analyzers are a cost efficient solution for manufacturing and laboratory.
RF Components that may cause PIM:
- Cables
- Connectors
- Antennas
- Attenuators, Loads
- Surge Protectors
- Filters, Diplexers, Duplexers
- Combiners, Splitters, Couplers
| Model Number | Type | Tx Frequency (MHz) | Rx Frequency (MHz) | Ports |
|---|---|---|---|---|
| PEMCTRL | Master Control Unit (controls up to 4 RF Units) | All | All | - |
| RF Units | ||||
| PEM385 | TETRA 385 | 385 – 400 | 410 – 425 | fwd / rev |
| PEM400 | TETRA 400 | 390 – 400 | 380 – 385 | fwd / rev |
| PEM400E | E-TETRA400 | 420 – 430 | 410 – 412 | fwd / rev |
| PEM700L | LTE 700 (Lower Band) | 728 – 759 | 698 – 716 | fwd / rev |
| PEM700U | LTE 700 (Upper Band) | 730 – 759 | 776 – 788 | fwd / rev |
| PEM800 | LTE 800 | 791 – 821 | 832 – 862 | fwd / rev |
| PEM850 | AMPS / CDMA | 869 – 896 | 824 – 851 | fwd / rev |
| PEM900E | EGSM | 890 – 915 | 925 – 960 | fwd / rev |
| PEM1500JP | LTE 1500-JP | 1488 – 1520 | 1456 – 1480 | fwd / rev |
| PEM1800 | DCS / GSM 1800 | 1805 – 1880 | 1710 – 1785 | fwd / rev |
| PEM1900 | PCS 1900 | 1930 – 1990 | 1850 – 1910 | fwd / rev |
| PEM2000TD | TD-SCDMA(2000) | 2010 – 2025 | 1900 – 1920 | fwd / rev |
| PEM2100AWS | AWS | 2010 – 2155 | 1710 – 1755 | fwd / rev |
| PEM2100UMTS | UMTS/W-CDMA | 2110 – 2170 | 1920 – 1980 | fwd / rev |
| PEM2160JP | W-CDMA-JP | 2150 – 2170 | 2110 – 2140 | fwd / rev |
| PEMWBKR | WiBro-KR | 2110 – 2170, 2300 – 2390 | 1910 – 1990 | fwd / rev |
| PEM2600LTE | IMT-E(2600) | 2620 – 2690 | 2500 – 2570 | fwd / rev |
| PEM3500LTE | IMT-E(3500) | 3510 – 3590 | 3410 – 3490 | rev |
| Accessories | |
|---|---|
| Model Number | Description |
| PCTRLCOM | Control Computer for PS2M, PD2M and PEM series Analyzer |
| PACC2 | Accessory Kit: low PIM cable 3m / 10ft, low PIM load 50/10W, 690-2800 MHz, -165dBc, (4) adapters, torque wrench with hard carry case |
| PACC2L | Accessory Kit: low PIM cables 3m / 10ft, low PIM load 100W, 380-2800 MHz, -165dBc, (4) adapters, torque wrench with hard carry case |
| PLOAD100 | Low PIM Load 100W, < 165 dBc @ 2* 43W, 690 – 2800 MHz, DIN 7/16 (f) |
| PLOAD100L | Low PIM Load 100W, < 165 dBc @ 2* 43W, 380 – 2800 MHz, DIN 7/16 (f) |
| PIMGEN | PIM Source: Generator with preset PIM value -80dBm (+/-10). Quick indication of system functionality. Ideal for test and training. |
| Transmitter | |
|---|---|
| Carrier Power | +20 to +44 dBm (46 dBm optional) |
| Power Accuracy | +/- 0.35 dB |
| Frequency Accuracy | 2 ppm |
| Reverse Pwr. Protection | +43 dBm for 5 sec |
| Receiver | |
|---|---|
| Reverse IM | -129 dBm / -172 dBc typ. (@ 2x43dBm) |
| Forward IM (units 700MHz and up) | -125 dBm / -168 dBc typ. (@ 2x43dBm) |
| Noise Floor | -140 dBm (300 Hz BW) |
| DynamicRange(typical) | > 96 dB (ref: -70 dBm) |
| Reverse Power Protection | +43 dBm for 5 sec |
| Operational Input Power | -40 dBm RMS |
| Max Input Power | 0 dBm |
| Measurement Accuracy | +/- 1.0 dB @ 2 x 43 dBm |
| Dimensions / Weight / Environment / Electrical | |
|---|---|
| Dimensions |
Control Unit: 483 x 305 x 500 (mm) RF Units (exc. E-GSM): 483 x 667 x 143 (mm) RF Units E-GSM: 483 x 756 x 143 (mm) |
| Weight |
Control Unit: 11.7 kg RF Units: 25 – 28 kg |
| Temperature | 0 °C to +40 °C |
| Humidity | 80 %, RH (non condensing) |
| Protection | IP20 |
| AC Power | 100 to 240V 50/60 Hz |
| Power Consumption |
Control Unit: 88 Watts (VA) RF Units: 700 Watts (VA) max |
Related Products
Support at Every Step
We provide support, services, comprehensive training and the resources you need. It’s all part of what we do to maximise the value of your VICOM investment.
Services
Value-add services that complement your VICOM system solution and instrument portfolio to provide a total cost of ownership.
Customer Care
Customer service that provides Return Material Authorisation (RMA) for repair and calibration.
Training
Technical education solutions, product training, and blended learning for technicians who are using new products or working with existing tools
Technical Assistance
Technical Assistance Center to assist you in using/configuring products or address issues regarding product performance
How to get started
Interested in a product demonstration? Contact us for more info, receive a price quote, or find out how to buy.
Contact Sales Expert