Vicom OTDR Selection GuideList 1: All OTDR Models |
NOTE: “Approx Distance” below refers to the approximate fibre distance that can accurately be certified based on 0.2dB/km fibre loss @ 1550nm (0.22dB for 1625/1650 only OTDRs) & 0.1dB splices every 2km. Note too that for the same distance, test times reduce with dynamic range increase – roughly half the test time for every 2-3dB increase in dynamic range.
Measurement Range (range of accurate measurement) is approx 8 dB less than Dynamic Range (range to find end-of-fibre)
MTS-4000 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
EM4000HVT & E4123MM | 1 | MM | 850/1300 | 26/24 | |
EM4000HVT & E4146QUAD |
1 2 |
SM MM |
1310/1550 850/1300 |
37/35 26/24 |
110-140 |
EM4000HVT & E4126LA | 1 | SM | 1310/1550 | 35/33 | 100-130 |
EM4000HVT & E4126MA2-PC | 1 | SM | 1310/1550 | 40/40 | 130-160 |
EM4000HVT & E4126MA3-APC | 1 | SM | 1310/1550 | 43/41 | 130-160 |
EM4000HVT & E4126MP2-PC | 1 | SM | 1310/1550/1625 | 46/45/44 | 150-180 |
MTS-2000 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
EM2000HVT & E4123MM | 1 | MM | 850/1300 | 26/24 | |
EM2000HVT & E4146QUAD |
1 2 |
SM MM |
1310/1550 850/1300 |
37/35 26/24 |
110-140 |
EM2000HVT & E4126LA | 1 | SM | 1310/1550 | 35/33 | 100-130 |
EM2000HVT & E4126MA2-PC | 1 | SM | 1310/1550 | 40/40 | 130-160 |
EM2000HVT & E4126MA3-APC | 1 | SM | 1310/1550 | 43/41 | 130-160 |
EM2000HVT & E4126MP2-PC | 1 | SM | 1310/1550/1625 | 46/45/44 | 150-180 |
SmartOTDR Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
E118FA65-APC | 1 | SM | filtered 1650 | 32 | 100-130 |
E118FA65PPM-APC | 1 | SM | filtered 1650 | 32 | 100-130 |
E126A-PC | 1 | SM | 1310/1550 | 37/35 | 110-140 |
E126A-APC | 1 | SM | 1310/1550 | 37/35 | 110-140 |
E138FA65-PC |
1 2 |
SM SM |
1310/1550 filtered 1650 |
37/35 32 |
110-140 |
E138FA65-APC |
1 2 |
SM SM |
1310/1550 filtered 1650 |
37/35 32 |
110-140 |
E126B-PC | 1 | SM | 1310/1550 | 40/40 | 130-160 |
E126B-APC | 1 | SM | 1310/1550 | 40/40 | 130-160 |
E136FB-PC |
1 2 |
SM SM |
1310/1550 filtered 1625 |
40/40 41 |
130-160 |
E136FB-APC |
1 2 |
SM SM |
1310/1550 filtered 1625 |
40/40 41 |
130-160 |
MTS-5800 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
EM5800HVT & E4123MM | 1 | MM | 850/1300 | 26/24 | |
EM5800HVT & E4146QUAD |
1 2 |
SM MM |
1310/1550 850/1300 |
37/35 26/24 |
110-140 |
EM5800HVT & E4126LA | 1 | SM | 1310/1550 | 35/33 | 100-130 |
EM5800HVT & E4126MA2-PC | 1 | SM | 1310/1550 | 40/40 | 130-160 |
EM5800HVT & E4126MA3-APC | 1 | SM | 1310/1550 | 43/41 | 130-160 |
EM5800HVT & E4126MP2-PC | 1 | SM | 1310/1550/1625 | 46/45/44 | 150-180 |
MTP-200X Series |
Optical Options
(Not applicable to each model variant, click below for full details of each model)
Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe
Model | Port # | Mode | Wavelength | Dynamic | Approx Distance |
(Click for Details) | Range | (see note above) | |||
(nm) | (dB) | (km) | |||
MTP-200X-20VC | 1 | SM | 1310/1550 | 38/37 | 120-150 |
MTP-200X-20VD | 1 | SM | 1310/1550 | 45/43 | 140-170 |
MTP-200X-20VF | 1 | SM | 1310/1550 | 50/48 | 160-190 |
MTP-200X-31VCPL | 1 | SM | 1310/1550 | 42/41 | 130-160 |
2 | SM | filtered 1625 | 40 | 120-150 | |
MTP-200X-33VC | 1 | SM | 1310/1550/1650 | 42/40/39 | 120-160 |
MTP-200X-40VC | 1 | SM | 1310/1550 | 38/36 | 110-140 |
2 | SM | 850/1300 | 23/36 |
palmOTDR SERIES |
Optical Options (Not applicable to each model variant, click below for full details of each model)
Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe
Model | Port # | Mode | Wavelength | Dynamic | Approx Distance |
(Click for Details) | Range | (see note above) | |||
(nm) | (dB) | (km) | |||
palmOTDR-M20AE | 1 | MM | 850/1300 | 21/24 | |
palmOTDR-S20AE | 1 | SM | 1310/1550 | 32/30 | 90-120 |
palmOTDR-S20BE | 1 | SM | 1310/1550 | 35/34 | 110-140 |
palmOTDR-S20C/N | 1 | SM | 1310/1550 | 40/38 | 120-150 |
palmOTDR-S20D/N | 1 | SM | 1310/1550 | 45/43 | 140-170 |
palmOTDR-S20F | 1 | SM | 1310/1550 | 50/48 | 160-190 |
palmOTDR-S20C/P | 1 | SM | 1310/1490/1550 | 38/37/37 | 120-150 |
palmOTDR-S20C/X | 1 | SM | 1310/1550 | 38/37 | 120-150 |
2 | SM | filtered 1625 or 1650 | 37 | 110-140 | |
palmOTDR-P11C | 1 | SM | filtered 1625 or 1650 | 37 | 110-140 |
palmOTDR-P31C | 1 | SM | 1310/1550 | 38/37 | 120-150 |
2 | SM | filtered 1625 | 37 | 110-140 | |
palmOTDR-Q40A | 1 | SM | 1310/1550 | 32/30 | 90-120 |
2 | MM | 850/1300 | 21/24 |