Vicom OTDR Selection Guide

List 1: All OTDR Models

contact_us_small.jpg

NOTE: Approx Distance” below refers to the approximate fibre distance that can accurately be certified based on 0.2dB/km fibre loss @ 1550nm (0.22dB for 1625/1650 only OTDRs) & 0.1dB splices every 2km. Note too that for the same distance, test times reduce with dynamic range increase – roughly half the test time for every 2-3dB increase in dynamic range.

Measurement Range (range of accurate measurement) is approx 8 dB less than Dynamic Range (range to find end-of-fibre)

 

VIAVI logo

MTS-4000 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM4000HVT & E4123MM 1 MM 850/1300 26/24  
EM4000HVT & E4146QUAD

1

2

SM

MM

1310/1550

850/1300

37/35

26/24

110-140 
EM4000HVT & E4126LA 1  SM 1310/1550 35/33 100-130 
EM4000HVT & E4126MA2-PC 1 SM 1310/1550 40/40 130-160 
EM4000HVT & E4126MA3-APC 1 SM 1310/1550 43/41 130-160 
EM4000HVT & E4126MP2-PC 1 SM 1310/1550/1625 46/45/44 150-180 

 

VIAVI logo

MTS-2000 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM2000HVT & E4123MM 1 MM 850/1300 26/24  
EM2000HVT & E4146QUAD

1

2

SM

MM

1310/1550

850/1300

37/35

26/24

110-140 
EM2000HVT & E4126LA 1  SM 1310/1550 35/33 100-130 
EM2000HVT & E4126MA2-PC 1 SM 1310/1550 40/40 130-160 
EM2000HVT & E4126MA3-APC 1 SM 1310/1550 43/41 130-160 
EM2000HVT & E4126MP2-PC 1 SM 1310/1550/1625 46/45/44 150-180 

 

VIAVI logo

SmartOTDR Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

E118FA65-APC 1 SM filtered 1650 32 100-130 
E118FA65PPM-APC 1 SM filtered 1650 32 100-130
E126A-PC 1 SM 1310/1550 37/35 110-140 
E126A-APC 1 SM 1310/1550 37/35 110-140 
E138FA65-PC

1

2

SM

SM

1310/1550

filtered 1650

37/35

32

110-140 
E138FA65-APC

1

2

SM

SM

1310/1550

filtered 1650

37/35

32

110-140 
E126B-PC 1 SM 1310/1550 40/40 130-160 
E126B-APC 1 SM 1310/1550 40/40 130-160 
E136FB-PC

1

2

SM

SM

1310/1550

filtered 1625

40/40

41

130-160 
E136FB-APC

1

2

SM

SM

1310/1550

filtered 1625

40/40

41

130-160 

 

VIAVI logo

MTS-5800 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM5800HVT & E4123MM 1 MM 850/1300 26/24  
EM5800HVT & E4146QUAD

1

2

SM

MM

1310/1550

850/1300

37/35

26/24

110-140 
EM5800HVT & E4126LA 1  SM 1310/1550 35/33 100-130 
EM5800HVT & E4126MA2-PC 1 SM 1310/1550 40/40 130-160 
EM5800HVT & E4126MA3-APC 1 SM 1310/1550 43/41 130-160 
EM5800HVT & E4126MP2-PC 1 SM 1310/1550/1625 46/45/44 150-180 

 

Shineway Technologies logo

MTP-200X Series

Optical Options

 (Not applicable to each model variant, click below for full details of each model)

Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe

Model Port # Mode Wavelength Dynamic Approx Distance
(Click for Details)       Range (see note above) 
      (nm) (dB) (km)
MTP-200X-20VC 1 SM 1310/1550 38/37 120-150
MTP-200X-20VD 1 SM 1310/1550 45/43 140-170
MTP-200X-20VF 1 SM 1310/1550 50/48  160-190
MTP-200X-31VCPL 1  SM 1310/1550 42/41 130-160
  2 SM  filtered 1625 40  120-150
MTP-200X-33VC 1 SM 1310/1550/1650 42/40/39 120-160
MTP-200X-40VC 1 SM 1310/1550 38/36  110-140
  2 SM 850/1300 23/36  

 

Shineway Technologies logo

palmOTDR SERIES

Optical Options (Not applicable to each model variant, click below for full details of each model)

Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe

Model Port # Mode Wavelength Dynamic Approx Distance
(Click for Details)       Range (see note above) 
      (nm) (dB) (km)
palmOTDR-M20AE 1 MM 850/1300 21/24  
palmOTDR-S20AE 1 SM 1310/1550 32/30 90-120
palmOTDR-S20BE 1 SM 1310/1550 35/34 110-140
palmOTDR-S20C/N  1  SM 1310/1550 40/38 120-150
palmOTDR-S20D/N 1 SM 1310/1550 45/43 140-170
palmOTDR-S20F 1 SM 1310/1550 50/48 160-190 
palmOTDR-S20C/P 1 SM 1310/1490/1550 38/37/37 120-150
palmOTDR-S20C/X 1 SM 1310/1550 38/37 120-150
  2 SM  filtered 1625 or 1650  37 110-140
palmOTDR-P11C 1 SM filtered 1625 or 1650 37 110-140
palmOTDR-P31C 1 SM 1310/1550  38/37  120-150 
  2 SM filtered 1625 37 110-140
palmOTDR-Q40A   1   SM 1310/1550  32/30 90-120 
  2  MM 850/1300  21/24