Flightline/Ramp Air Data Test Sets
Portable, Reliable, High Accuracy, Multi-output, Battery Powered, Configurable ADTS
|
Overview
With over 60 years experience in the design and manufacture of Air Data Test sets, DMA-Aero offer an extensive range of RVSM and Domestic RVSM (DRVSM) compliant air data test systems. These aircraft pitot static testers are ideal for all work on pitot-static systems such as: leak testing; troubleshooting and full certification. With a wide range of base models and an extensive complement of options the ADTS are ideal for all pitot static air data test requirements. Precision pressure sensors are utilized, together with low power consumption which generates negligible heat, to achieve the highest accuracy available today. Offering +/- 3 feet or better at sea level, the pitot-static test sets meet the stringent requirements for RVSM certification testing. The instruments are all ready for use and within the accuracy band at the conclusion of the initialization / self test procedure.
The air data testers are all digitally controlled through a local or remote keypad and display. The intuitive user interface allows test set functions to be easily controlled with a minimum of key strokes, with all test parameters displayed, and is suitable for both first time and more advanced users. Optionally many of the ADTS can be remotely controlled by a tablet PC with wireless Bluetooth connection. The intelligent user interface provides protection to both the test set and the UUT. The software rejects entered command values that exceed the pre-selected limit ranges. Limits can be easily changed and are password protected for security. A pressure condition of Ps greater than Pt is prevented in both manual and automatic operation. With loss of power the test circuit is safely isolated and can be manually vented preventing instrument and test set damage.
The ADTS are applicable to all types of civil and extended range, fixed or rotary wing, aircraft pitot-static testing.
Twin channel instruments in the range include the ultra compact MPS43B RVSM ADTS that weighs just 10 lbs. while providing full automatic control with RVSM accuracy. The MPS43H variant is especially configured for use with helicopters. As well as our latest civil range ADTS, the MPS45, we also have the MPS34C that provides laboratory accuracy on the flightline. The 3 channel series of instruments control three pressures separately and independently to verify the Angle of Attack (AoA) as well as Static and Pitot pressures, for use with 'Smart' type pitot tubes. Our latest 3 channel instrument is the MPS49 with the MPS39C also being available. The MPS40C is a 4 channel ADTS with 2 channels of AoA.
The latest MPS45 and MPS49 aircraft pitot-static test sets offer up to 12 switched output ports, extended calibration interval and other improved specifications and capabilities. The MPS45HF is a high flow variant of the MPS45 for aircraft with large pitot-static system volumes.
On most models internal static and pitot multiple isolators and output ports are available. Different static and pitot values can be locked into the appropriate leak free lines for checking the altitude comparator and similar functions. A new method for leak testing (one line in control mode while the other is in measure mode) ensures higher safety and avoids wasted testing time.
All the flightline/ramp Air Data Test Sets are portable and can also be used in the laboratory with either ADWIN PC software, or under control of an ATE system. They all have battery power either fitted as standard or available as an option. This allows the Air Data Test Set to be used where ac power is unavailable or for ADTS operation to continue during power failure. All the test sets are engineered to minimize power consumption which extends battery life. The compact MPS43 has battery power only for safe return to ground conditions.
All models have internal pumps which run 'on demand' to reach maximum life duration associated with low electrical power consumption. Noise level is very low, a welcome feature when the ADTS is used in the workshop. Most models contain DMA's specially engineered high reliability 5,000 hour warranted pump.
On all ADTS, 30 User test profiles are programmable and executable, each with 26 test points, ideal for FAR43/FAR91 testing. Some models are fitted with a Compact Flash memory card for storing results. Calibration adjustments are made by software input only with no hardware adjustment required. A comprehensive list of options is available with some models being pre-configured for certain options. Amongst the available options are:
- 28 VDC operation
- IEEE488 control (RS232 control is standard on most models)
- ARINC429 interface
- Bluetooth control by tablet PC
- Ethernet and Wi-Fi interfaces
- Multiple isolated static and pitot outputs controlled from the keypad
- ADWIN software for PC control
- Hand held remote control unit
- Encoding altimeter readout
- Extended ranges of 850 or 1,000 kts
- Internal battery
- External battery to extend battery life
- External pressure and vacuum supply
Please inquire on any other option requirements such as radio altimeter automatic test.
A large range of pitot-static adapters can be supplied both individually and in kit form. Visit our pitot-static adapters and air data accessory kits page.
Laboratory Air Data Test Sets
DMA is a leading manufacturer of ADTS models for laboratory RVSM and DRVSM compliant air data testing with the highest accuracy and resolution. The MPS46 Air Data Test Set uses a special characterization for maximum accuracy (< 2 feet at sea level for static channel). Pressure resolution of 0.2 Pa.is also achievable. It is digitally controlled through a user keyboard and touchscreen display and the human interface ensures that all the functions are controlled with a minimum of key presses. The ADTS can also be used in avionics ATE systems (rack is only 2U high) via RS232, USB, Ethernet or GPIB/IEEE488 or controlled from a PC with ADWIN control software. An internal pump or EPSR2 external rack mounted pump unit can be supplied as an option. Many of the functions and option capabilities are in common with the flight line air data test systems. The 3U high MPS56 is also available as a very high flow rate version of the MPS46. The EPSR3 external rack mounted pump unit provides pressure and vacuum supplies for the MPS56.
MPS40C | MPS43B | MPS45 | MPS45HF | MPS46/56 | MPS49 | |
Accuracy | Hi | Hi | Hi | Hi | Very Hi | Hi |
Case | Flightline | Flightline | Flightline | Flightline | Rack | Flightline |
Size | Large | Ultra compact | Medium | Medium | 2U High (MPS56 3U) | Medium |
Range Alt | Max | Medium | Max | Max | Max | Max |
Large Pump | Yes | No | Yes | Yes | Option | Yes |
Keyboard | Yes | Yes | Yes | Yes | Yes | Yes |
Hand Terminal | Yes | Option | Yes | Option | No | Yes |
USB port | Yes | No | Yes | Yes | No | Yes |
Battery | Yes-4hr | Yes-1Hr+ | Yes-2hr | Yes-2hr | No | Yes-2hr |
4+4 Isolate | Option | No | Option | Option | No | Option |
3+3 Isolate | No | No | Option | Option | Option | Option |
2+2 Isolate | No | No | Option | Option | Option | Option |
Bluetooth Remote | Option | Yes | Option | Option | No | Option |
Alt. Encoder | Option | Option | Option | Option | Option | Option |
Angle of Attack (AoA) | Yes x2 | No | No | No | No | Yes |
GPIB | Option | No | Option | Option | Option | Option |
28V DC | Option | Option | Option | Option | ||
ARINC | Option | No | Option | Option | Option | Option |
Channels | 4 | 2 | 2 | 2 | 2 | 3 |
Product Range
Download Datasheets
|
|
|
||
|
|
|
Control Terminals
The handheld remote control, the MPSRE (MPSRE2 for the MPS45 and MPS49) touch screen remote terminal or the MPSRC terminal (for MPS45 and MPS49) provide alternative forms of remote control for the Air Data Test Sets. The MPSRE includes a USB port for test program download and results storage. The MPSRW allows wireless control of any of the MPSxxx range of ADTS and connects via Bluetooth or Wi-Fi. |
|
|
|
|
|
|||
Handheld Remote | MPSRC | MPSRE | MPSRW | |||
Handheld Remote |
The MPSRC is a new design offering essentially a convenient duplicate of the console mounted features of color touch panel screen and adjacent keyboard all housed in a ergonomically styled case that is comfortable to grasp in the hand while operating from within the aircraft. The design provides a rugged, splash proof unit weighing only 0.5 kg (1.1lb |
The MPSRE Remote Touch Screen terminal provides an alternative control unit for all ADTS. It includes a USB port for test program download and results storage. The MPSRE2 is used with the MPS45 and MPS49 | Wireless touchscreen remote terminal to control any of the MPSxxx instruments. Connects via Bluetooth or Wi-Fi |
Training Videos
MPS43B |
MPS45/49 |
MPS39C |
MPS31C |
MPS43 |
Get In Touch